AC motors are manufactured with a laminated core iron. Each lamination is individually insulated to prevent circulating currents within the core iron that creates hot spots. CMT will core loss test a wound stator prior to burnouts of windings in a temperature controlled, monitored oven to remove varnish and allow for easier coil removal. A […]
Motor winding both AC and DC available at CMT
AC motors are manufactured with a laminated core iron that is insulated and wound with copper conductors. Over time, motor windings age and fail due to usage. CMT can remanufacture any size AC motors to original specifications. Our initial burnout process includes testing core loss before and after and charting oven temperature. The core iron […]